Manufacturer: Schneider Electric
Model: GV2ME06 TeSys GV2 Motor Circuit Breaker
Setting Range: 1 … 1.6 A
Rated Current: 1.6 A (thermal-magnetic trip)
Breaking Capacity: 100 kA @ 400/415 V (Icu, IEC 60947-2)
Control: Pushbutton control, 3-pole

Product Description

The Schneider Electric GV2ME06 is the world’s most popular compact motor circuit breaker for small motors in the 0.37–0.75 kW range at 400 V. Part of the legendary TeSys GV2 series that has protected millions of motors worldwide, it combines thermal-magnetic trip unit (Class 10), ultra-high short-circuit breaking capacity, phase failure sensitivity and manual isolation in an ultra-compact 45 mm wide package. Pushbutton operation and direct DIN-rail mounting make it the default choice for DOL starters, machine tools, pumps, fans and countless small-motor applications globally.

Standard Features

  • Perfect for 0.37–0.75 kW motors: 1–1.6 A setting range covers the majority of small three-phase motors.

  • 100 kA breaking capacity: Highest short-circuit performance in its class — safe even in high-fault networks.

  • Pushbutton control: Instant manual ON/OFF + clear trip indication — no separate contactor needed for basic DOL.

  • Phase failure & imbalance protection: Built-in differential thermal trip — protects against single-phasing.

  • Add-on blocks compatible: Accepts all GV2/GV3 auxiliaries, under-voltage and shunt trips, door operators.

  • Global approvals: UL 60947-4-1 (Type E), CSA, CE, CCC — accepted everywhere.

Technical Specifications

ParameterValue
TypeThermal-magnetic motor circuit breaker
Order NumberGV2ME06
Rated Operational Voltage (Ue)690 VAC
Setting Range (Ir)1 … 1.6 A
Ultimate Breaking Capacity (Icu)100 kA @ 400/415 V, 50 kA @ 440 V, 15 kA @ 690 V
Trip ClassClass 10A (IEC 60947-4-1)
Motor Power 400/415 V0.37 … 0.75 kW
Control TypePushbutton (red/green)
Poles3-pole with phase failure protection
Mounting35 mm DIN-rail or screw fixing
Width45 mm
ConnectionScrew clamp terminals 1–6 mm² (flexible/rigid)
Degree of ProtectionIP20 (terminals), IP54 with cover
Operating Temperature–20 °C … +60 °C
Standards & ApprovalsIEC/EN 60947-2, 60947-4-1, UL 60947-4-1 (Type E), CSA C22.2 No.60947-4-1, CE, CCC, EAC, Marine
e="font-size: 14px;">ParameterValueTypeThermal-magnetic motor circuit breakerOrder NumberGV2ME05Rated Operational Voltage (Ue)690 VACSetting Range (Ir)0.63 … 1 AUltimate Breaking Capacity (Icu)100 kA @ 400/415 V, 50 kA @ 440 V, 15 kA @ 690 VTrip ClassClass 10A (IEC 60947-4-1)Motor Power 400/415 V0.18 … 0.37 kWControl TypePushbutton (red/green)Poles3-pole with phase failure protectionMounting35 mm DIN-rail or screw fixingWidth45 mmConnectionScrew clamp terminals 1–6 mm² (flexible/rigid)Degree of ProtectionIP20 (terminals), IP54 with coverOperating Temperature–20 °C … +60 °CStandards & ApprovalsIEC/EN 60947-2, 60947-4-1, UL 60947-4-1 (Type E), CSA C22.2 No.60947-4-1, CE, CCC, EAC, Marine