Schneider GV4PEM50N Motor Circuit Breaker Supplier | SIMPLYBUY
海报

Schneider GV4PEM50N Motor Circuit Breaker

Rated Current: Schneider Electric
Protection Modes: Magnetic protection, electronic thermal-magnetic protection, and adjustable protection functions
Additional Features: It can be equipped with an SDx side module for alarm and fault diagnosis
This model is designed for versatile motor protection, offering adjustable settings and advanced fault detection capabilities.

Product Description

The TeSys GV motor circuit breaker is a 3-pole (3P) device rated at 50A/690V, designed for protecting 3-phase motors ranging from 11-22kW at 400V.


Protection Features
This multifunction circuit breaker provides both thermal-magnetic protection and advanced motor protection features.

  • Breaking capacity: Icu 50kA at 400V, ensuring reliable fault current interruption.

  • Magnetic protection: Fixed at 17 In for short-circuit protection.


Control and Connectivity

  • Start-stop control via a convenient toggle switch.

  • Everlink BTR screw terminals ensure secure and durable connections.


Adjustable Thermal Protection

  • Dial-adjustable setting current (Ir) range: 20-50A.

  • Selectable tripping class: 10 or 20.


Advanced Protection Functions (Configurable via NFC)

  • Short time delay protection (Isd): Adjustable from 5 to 13 times Ir

  • Phase unbalance and loss protection

  • Ground fault protection

  • Locked rotor (jam) protection

  • Long start protection


Expandability and Accessories

  • Internal slots available for auxiliary contact blocks (OF, SD) and voltage trip units (MN, MX).

  • Supports up to 2 external auxiliary SDx modules for alarm and fault differentiation.


Certifications
Compliant with multiple international standards: IEC, UL, CSA, CCC, EAC, Marine, and ATEX.


Applications
A versatile and reliable solution for industrial motor protection in a variety of environments.

Standard Features

Schneider GV4PEM50N Motor Circuit Breaker Key Features

  • 1 Overload Protection:Adjustable thermal trip bimetallic for sustained overcurrent rated 50A
  • 2 ShortCircuit Protection:Instant magnetic trip for highcurrent faults
  • 3 Manual Control and Isolation:ONOFF switching and safe disconnection
  • 4 Adjustable Settings : Customizable trip thresholds for overload and shortcircuit
  • 5 Status Indicators:Visual ONOFF and fault alerts
  • 6 Modular Accessories: Supports auxiliary contacts shunt releases

Technical Specifications

AttributeAttribute Value
Range of ProductTeSys GV4
RangeTeSys Deca
Device short nameGV4PEM
Product nameTeSys GV4
Product or Component TypeMotor circuit breaker
Device ApplicationMotor protection
Trip unit technologyElectronic
Thermal-magnetic
Poles description3P
Utilisation categoryCategory A IEC 60947-2
AC-3 IEC 60947-4-1
Operating positionAny position
Motor power kW11 kW 400...415 V AC 50/60 Hz
15 kW 500 V AC 50/60 Hz
18.5 kW 660...690 V AC 50/60 Hz
15 kW 400...415 V AC 50/60 Hz
18.5 kW 400...415 V AC 50/60 Hz
22 kW 400...415 V AC 50/60 Hz
18.5 kW 500 V AC 50/60 Hz
22 kW 500 V AC 50/60 Hz
30 kW 500 V AC 50/60 Hz
22 kW 660...690 V AC 50/60 Hz
30 kW 660...690 V AC 50/60 Hz
37 kW 660...690 V AC 50/60 Hz
45 kW 660...690 V AC 50/60 Hz
Breaking capacity100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2
50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2
50 kA Icu 440 V AC 50/60 Hz IEC 60947-2
15 kA Icu 525 V AC 50/60 Hz IEC 60947-2
65 kA 208Y/120 V AC 50/60 Hz UL 60947
65 kA 240 V AC 50/60 Hz UL 60947
35 kA 480Y/277 V AC 50/60 Hz UL 60947
8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2
25 kA Icu 500 V AC 50/60 Hz IEC 60947-2
18 kA 600Y/347 V AC 50/60 Hz UL 60947
Control TypeToggle
Line Rated Current50 A
Magnetic tripping current850 A
[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage800 V AC 50/60 Hz IEC 60947-2
[Ith] conventional free air thermal current115 A IEC 60947-4-1
[Uimp] rated impulse withstand voltage8 kV IEC 60947-2
Power dissipation per pole4.6 W

Read More

Get a Quote

    Get A Quote

      Download Catalog