Masterpact MT Supplier | SIMPLYBUY
海报

Masterpact MT

Manufacturer: Schneider Electric
Model: Masterpact MT
Type: Air Circuit Breakers
Relay application: 630~6300A
Key Sourcing Insight: A cost-effective alternative to Schneider NW ACBs, with shorter lead times and professional configuration support.

Product Description

Masterpact MT adopts new technology to enhance product performance and safety. It is a new-age product with easy installation, user-friendly interface, convenient operation and easy design.

Supply Advantage & Procurement Notes

The Masterpact MT air circuit breaker serves as a cost-effective alternative to the Schneider NW series, offering lower pricing and shorter lead times.

Because domestic and international models differ, selection requires precise parameter matching and accessory configuration—capabilities many suppliers are unable to support reliably.

NW Series Alternative Shorter Lead Time Parameter & Accessory Matching

Standard Features

Masterpact MT series circuit breakers have drawer type/fixed type, 3/4 pole switch Provide load switch, 1000V, and DC products, divided into seven breaking types:

  • N1: Current level 630A to 1600A, breaking capacity 50KA, standard type, suitable for breaking low-level short-circuit current
  • N2: Current level 800A to 2500A, breaking capacity 50KA, suitable for general applications
  • H1: Current level 800A to 6300A, breaking capacity 65KA, suitable for breaking high-level short-circuit current in industrial environments or electrical systems with two transformers running in parallel
  • H1b: Current level 800A to 4000A, breaking capacity 85kA, suitable for industrial industries with large short-circuit currents
  • H2: Current level 800A to 6300A, breaking capacity 100KA, high-performance type, suitable for heavy industrial fields that may generate very high short-circuit currents
  • H3: Current level 800A to 4000A, breaking capacity 150KA, suitable for occasions that require both high-performance breaking capacity and high-level coordination
  • L1: Current level 800A to 2000A, breaking capacity 150KA, with high current limiting capability to protect the feeder unit or improve the performance level of the switchgear when the rated power of the transformer is increased

Technical Specifications

Breaking capacityRated currentTransformer RatingNumber of polesIntelligent controller protection type
N2 50kA08:800A 10:1000A 12:1250A 16:1600A 20:2000A 25:2500A400A 630A 800A 1000A 1250A 1600A 2000A 2500A3-pole
4-pole conventional configuration [neutral pole on the left side of the circuit breaker]
MIC 2.0 LI basic protection
MIC 5.0 LSI selective protection
MIC 6.0 LSI selective protection and ground fault protection
MIC 7.0 LSI selective protection and leakage protection
H1 65kA08:800A 10:1000A 12:1250A 16:1600A 20:2000A 25:2500A 32:3200A 40:4000A400A 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A3-pole
4-pole conventional configuration [neutral pole on the left side of the circuit breaker]
4-pole special configuration [neutral pole on the right side of the circuit breaker]
H1b 85kA08:800A 10:1000A 12:1250A 16:1600A 20:2000A 25:2500A 32:3200A 40:4000A400A 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A3-pole
4-pole conventional configuration [neutral pole on the left side of the circuit breaker]
H1 100kA40b:4000 50:5000A 63:6300A2000A 2500A 3200A 4000A 5000A 6300A3-pole
4-pole conventional configuration [neutral pole on the left side of the circuit breaker]
4-pole special configuration [neutral pole on the right side of the circuit breaker]
MIC 2.0 LI basic protection
MIC 5.0 LSI selective protection
MIC 6.0 LSI selective protection and ground fault protection
H2 100kA08:800A 10:1000A 12:1250A 16:1600A 20:2000A 25:2500A 32:3200A 40:4000A400A 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A3-pole
4-pole conventional configuration [neutral pole on the left side of the circuit breaker]
4-pole special configuration [neutral pole on the right side of the circuit breaker]
MIC 2.0 LI basic protection
MIC 5.0 LSI selective protection
MIC 6.0 LSI selective protection and ground fault protection
MIC 7.0 LSI selective protection and leakage protection
H2 150kA40b:4000 50:5000A 63:6300A2000A 2500A 3200A 4000A 5000A 6300AMIC 2.0 LI basic protection
MIC 5.0 LSI selective protection
MIC 6.0 LSI selective protection and ground fault protection
H3 150kA20:2000A 25:2500A 32:3200A 40:4000A2000A 2500A 3200A 4000A3-pole
4-pole conventional configuration [neutral pole on the left side of the circuit breaker]
MIC 2.0 LI basic protection
MIC 5.0 LSI selective protection
MIC 6.0 LSI selective protection and ground fault protection
MIC 7.0 LSI selective protection and leakage protection
L1 150kA  08:800A 10:1000A 12:1250A 16:1600A 20:2000A400A 630A 800A 1000A 1250A 1600A 2000A
Intelligent controller protection typeOrder NumberMX-shunt coilXF-closing coilMCH-Energy Storage Motor
Micrologic 2.065302484914848148522
Micrologic 2.0A48358484924848248526
Micrologic 2.0E48498484934848348527
Micrologic 5.065303484944848448528
Micrologic 5.0A48360484954848548529
Micrologic 5.0E48499484964848648530
Micrologic 5.0D65472484584844948521
Micrologic 5.0P48363484594845048523
Micrologic 5.0H48366484604845148524
Micrologic 6.0654084846148452 
Micrologic 6.0A483614846248453 
Micrologic 6.0E485004846348454 
Micrologic 6.0D65475   
Micrologic 6.0P48364   
Micrologic 6.0H48367   
Micrologic 7.0A48362   
Micrologic 7.0P48365   
Micrologic 7.0H48368   

Read More