CHINT NXM‑400S/3300 400A Molded Case Circuit Breaker – 400A, 3‑Pole, 50kA @ 400V, Thermal‑Magnetic Trip Supplier | SIMPLYBUY
海报

CHINT NXM‑400S/3300 400A Molded Case Circuit Breaker – 400A, 3‑Pole, 50kA @ 400V, Thermal‑Magnetic Trip

Manufacturer: CHINT Electric
Model: NXM-400S/3300 400A
Type: Molded Case Circuit Breaker
Rated Current: 400 A
Number of Poles: 3
Breaking Capacity: 50 kA @ 400 V AC
Trip Unit: Thermal-Magnetic

Product Description

The CHINT NXM-400S/3300 400A is a three-pole molded case circuit breaker from the NXM (Kunlun) series, designed for protection against prolonged overloads and short-circuit currents in low-voltage distribution networks. It features a thermal-magnetic trip unit with a fixed rated current of 400 A, providing reliable inverse-time overload protection and instantaneous magnetic short-circuit protection. The breaker delivers an ultimate short-circuit breaking capacity of 75 kA at 220–240 V AC and 50 kA at 380–415 V AC, with a rated insulation voltage of 1000 V. Its compact frame with front-connection terminals accommodates cables up to 240 mm². Typical applications include industrial power distribution, commercial building mains, and machinery protection.

Standard Features

  • Thermal-Magnetic Trip Unit: Provides inverse-time overload protection and instantaneous magnetic short-circuit protection for reliable circuit and equipment safeguarding.
  • High Breaking Capacity: Ultimate short-circuit breaking capacity of 75 kA at 220–240 V AC and 50 kA at 380–415 V AC ensures robust fault current interruption.
  • Three-Pole Fixed Configuration: Compact 3P design with front-connection terminals simplifies installation in switchboards and distribution panels.
  • Wide Rated Voltage Range: Rated operational voltage of 220–415 V AC with rated insulation voltage of 1000 V, suitable for diverse low-voltage applications.
  • High Electrical and Mechanical Life: Electrical life of 8,000 operations at 415 V AC / In and mechanical life of 20,000 operations with maintenance (10,000 without).
  • IP30 Protection Degree: Provides protection against solid objects greater than 2.5 mm, suitable for general industrial environments.
  • IEC 60947-2 Compliance: Conforms to GB/T 14048.2 and IEC 60947-2 standards, with CCC, KEMA, CB, and NOM certifications.

Technical Specifications

ParameterValue
ManufacturerCHINT Electric
ModelNXM-400S/3300 400A
SeriesNXM (Kunlun)
Product TypeMolded Case Circuit Breaker (MCCB)
Rated Current (In)400 A
Number of Poles3
Trip Unit TypeThermal-Magnetic (fixed)
Rated Operational Voltage (Ue)220/230/240 V AC, 380/400/415 V AC
Rated Insulation Voltage (Ui)1000 V
Rated Impulse Withstand Voltage (Uimp)12 kV
Breaking Capacity (Icu) @ 380/400/415 V AC50 kA
Breaking Capacity (Icu) @ 220/230/240 V AC75 kA
Connection Capacity240 mm²
Ambient Operating Temperature-35…+70 °C
Degree of ProtectionIP30
StandardsGB/T 14048.2, IEC 60947-2

Get a Quote

    ✕

    Get A Quote

      ✕

      Download Catalog