Mitsubishi Electric NV63-CV 3P 30A Interruptor Automático de Corriente Residual – 30A, 3 Polos, Sensibilidad 30mA, 5kA @ 400V Proveedor | SIMPLYBUY
海报

Mitsubishi Electric NV63-CV 3P 30A Interruptor Automático de Fugas a Tierra – 30A, 3 Polos, Sensibilidad 30mA, 5kA @ 400V

Fabricante: Mitsubishi Electric
Modelo: NV63-CV 3P 30A
Tipo: Interruptor de Fuga a Tierra (ELCB)
Corriente nominal: 30 A
Número de polos: 3
Capacidad de ruptura: 5 kA @ 400 V AC
Sensibilidad de corriente residual: 100 / 200 / 500 mA (adjustable)

Descripción del Producto

The Mitsubishi Electric NV63-CV 3P 30A is a moulded case circuit breaker with embedded earth leakage protection from the WS-V series (NV-C economy class). It combines thermal-magnetic overcurrent protection with high-speed earth leakage detection in a single compact device. The thermal protection tripping threshold is fixed at 30 A, while the residual current sensitivity is configurable across 100 mA, 200 mA, and 500 mA. The breaker delivers an ultimate short-circuit breaking capacity of 7.5 kA at 230 V AC and 5 kA at 400 V AC, with service breaking capacity equal to 100% of Icu at 400 V AC. Its utilisation category A and pollution degree 2 rating make it suitable for industrial and commercial distribution boards requiring combined overload, short-circuit, and earth leakage protection.

Características estándar

  • Combined Earth Leakage & Overcurrent Protection: Integrates thermal-magnetic overcurrent protection with high-speed earth leakage detection in a single device, reducing panel space and wiring complexity.
  • Adjustable Residual Current Sensitivity: Earth leakage sensitivity is selectable at 100 mA, 200 mA, or 500 mA to suit different protection requirements.
  • High-Speed Earth Leakage Detection: Maximum operating time of 0.1 s at rated residual current ensures rapid disconnection under fault conditions.
  • Reliable Breaking Capacity: Icu of 7.5 kA at 230 V AC and 5 kA at 400 V AC, with Ics equal to 100% of Icu at 400 V AC for dependable fault interruption.
  • Thermal-Magnetic Fixed Trip Unit: Fixed thermal protection at 30 A and magnetic short-circuit protection ensure consistent and predictable operation.
  • Compact & Space-Saving Design: Dimensions of 75 mm × 130 mm × 90 mm (W × H × D) with front lug or bar connections for easy panel installation.
  • High Durability & Global Compliance: 6,000 electrical operations and 10,000 mechanical operations; conforms to IEC 60947-2 and EN 60947-2 with CE marking.

Especificaciones técnicas

ParámetroValor
FabricanteMitsubishi Electric
ModeloNV63-CV 3P 30A
SerieWS-V series / NV-C (Economy Class)
Tipo de productoInterruptor de Fuga a Tierra (ELCB)
Corriente nominal (In)30 A
Número de polos3 (3P)
Tamaño de Bastidor (AF)50 A
Sensibilidad de corriente residual100 / 200 / 500 mA (adjustable)
Tensión nominal de funcionamiento (Ue)100–440 V AC
Breaking Capacity (Icu) @ 400 V AC5 kA
Tipo de unidad de disparoThermal-Magnetic (fixed)
Dimensiones (An × Al × Pr)75 mm × 130 mm × 90 mm
NormasIEC 60947-2, EN 60947-2

Obtenga una cotización

    ✕

    Obtenga una cotización

      ✕

      Descargar catálogo