Schneider Electric GV3P73 TeSys GV3 Motor Circuit Breaker – 73A, 3‑Pole, 37kW @ 400V, Thermal‑Magnetic Protection Supplier | SIMPLYBUY
海报

Schneider Electric GV3P73 TeSys GV3 Motor Circuit Breaker – 73A, 3‑Pole, 37kW @ 400V, Thermal‑Magnetic Protection

Manufacturer: Schneider Electric
Model: GV3P73
Type: Motor Circuit Breaker
Rated Current: 73 A
Thermal Setting Range: 62…73 A
Motor Power: 37 kW @ 400/415 V AC
Breaking Capacity: 50 kA @ 400/415 V AC
Number of Poles: 3P

Product Description

The Schneider Electric GV3P73 is a three-pole thermal-magnetic motor circuit breaker from the TeSys GV3 range, designed for manual start-stop control and reliable protection of motors in industrial applications. It features an adjustable thermal protection range from 62 A to 73 A and a fixed magnetic tripping current of 1120 A (15 × In), providing precise overload and short-circuit protection for motors up to 37 kW at 400/415 V AC. The rotary knob control is rated for 20,000 operating cycles (AC-3 at 415 V) and is padlockable for safe maintenance. With an ultimate breaking capacity of 50 kA at 400/415 V AC and 65 kA at 230/240 V AC, it delivers robust fault current interruption. EverLink BTR screw clamp terminals ensure reliable, low-resistance connections. The device is suitable for DIN rail or panel mounting and is certified to IEC, UL, CSA, CCC, EAC, ATEX, and marine standards.

Standard Features

  • Adjustable Thermal Protection: Thermal overload setting range of 62…73 A allows precise adaptation to the motor’s full-load current for optimal protection.
  • Fixed Magnetic Tripping: Magnetic short-circuit trip set at 1120 A (15 × In) ensures fast and reliable fault clearing.
  • High Breaking Capacity: 50 kA Icu at 400/415 V AC and 65 kA at 230/240 V AC provide robust protection in demanding installations.
  • Rotary Knob Control: Manual start-stop operation with a padlockable rotary knob, rated for 20,000 cycles (AC-3 at 415 V).
  • EverLink BTR Terminals: Patented screw clamp terminals maintain constant tightening pressure for reliable, maintenance-free connections.
  • Phase Failure Sensitivity: Detects phase loss to prevent motor damage from unbalanced supply conditions.
  • Compact DIN Rail Mounting: 55 mm wide, 132 mm high, 136 mm deep; clips onto 35 mm DIN rail or mounts on panel with M4 screws.

Technical Specifications

ParameterValue
ManufacturerSchneider Electric
ModelGV3P73
SeriesTeSys GV3 / TeSys Deca
Product TypeMotor Circuit Breaker (Manual Starter and Protector)
Rated Current (In)73 A
Number of Poles3P
Thermal Protection Range62…73 A (adjustable)
Magnetic Tripping Current1120 A
Motor Power (AC-3)37 kW at 400/415 V AC; 45 kW at 500 V AC; 55 kW at 690 V AC
Breaking Capacity (Icu)65 kA at 230/240 V AC; 50 kA at 400/415 V AC; 50 kA at 440 V AC; 12 kA at 500 V AC; 6 kA at 690 V AC
Rated Operational Voltage (Ue)690 V AC
Rated Impulse Withstand Voltage (Uimp)6 kV
Control TypeRotary knob (padlockable)
Connection TypeEverLink BTR screw clamp terminals
Mounting35 mm DIN rail (clipped) or panel (3 × M4 screws)
Dimensions (W × H × D)55 mm × 132 mm × 136 mm
Net Weight0.96 kg
Degree of ProtectionIP20
Ambient Operating Temperature-20…60 °C
Standards & CertificationsIEC 60947-2, IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1; CCC, UL, CSA, EAC, ATEX, Marine, UKCA

Get a Quote

    ✕

    Get A Quote

      ✕

      Download Catalog