Schneider Electric 50440 VigiPacT MA120 Closed Toroid – 120 mm Inner Diameter, 250 A, Type A, 1/1000 Ratio Supplier | SIMPLYBUY
海报

Schneider Electric 50440 VigiPacT MA120 Closed Toroid – 120 mm Inner Diameter, 250 A, Type A, 1/1000 Ratio

سازنده: اشنایدر الکتریک
مدل: 50440
نوع: Earth Leakage Current Sensor (Closed Toroid)
سری: VigiPacT MA120
جریان نامی: ۲۵۰ الف
Inner Diameter: 120 mm
Transformer Ratio: 1/1000
Current Sensor Type: نوع A

توضیحات محصول

The Schneider Electric 50440 is a Type A closed toroid from the VigiPacT range, designed as a residual current sensor for earth leakage protection and insulation fault monitoring. It features a 120 mm inner diameter and a 250 A rated operational current, with a transformer ratio of 1/1000 for precise residual current measurement. The toroid is compatible with VigiPacT RH-series residual current relays and Vigilohm insulation fault locators, enabling continuous monitoring of the power supply and the relay/toroid link. With an 85 kA/0.5 s short-time withstand current, 1000 V rated insulation voltage, and overvoltage category IV, it delivers reliable performance in demanding industrial and commercial power distribution systems.

ویژگی‌های استاندارد

  • Type A Residual Current Sensing: Detects AC and pulsating DC residual currents, meeting the requirements of modern earth leakage protection for equipment with electronic loads.
  • 120 mm Inner Diameter: Accommodates cable outer diameters up to 60 mm and maximum conductor cross-sections up to 240 mm², simplifying installation around large cables and busbars.
  • 250 A Rated Operational Current: Supports continuous monitoring of circuits up to 250 A, suitable for feeder and branch protection in industrial and commercial distribution boards.
  • 1/1000 Transformer Ratio: Provides precise and consistent residual current measurement for accurate coordination with VigiPacT protection relays.
  • 85 kA/0.5 s Short-Time Withstand: Withstands high fault currents without damage, ensuring reliability in demanding power distribution environments.
  • Reinforced Insulation (Overvoltage Category IV): Offers enhanced dielectric strength and safety for use at the origin of installations and in harsh electrical environments.
  • Versatile Mounting Options: Supports fixed mounting on cables, plain or slotted backplates, profiled sheet metal, and clip-on DIN rail mounting for flexible panel integration.

مشخصات فنی

پارامترارزش
تولیدکنندهاشنایدر الکتریک
مدل50440
سریویجی‌پک‌تی
نام کوتاه دستگاهMA120
نوع محصولEarth Leakage Current Sensor (Closed Toroid)
Current Sensor TypeType A closed toroid
جریان عملیاتی نامی (Ie)۲۵۰ الف
Transformer Ratio1/1000
Inner Diameter120 mm
Rated Short-Time Withstand Current (Icw)85 kA for 0.5 s
ولتاژ عایق نامی (UI)۱۰۰۰ ولت
ولتاژ تحمل ضربه نامی (Uimp)12 kV
دسته بندی ولتاژ اضافهIV
فرکانس شبکه45…440 Hz
ابعاد (ارتفاع × عرض × عمق)164 mm × 190 mm × 44 mm
وزن خالص0.59 kg
دمای عملیاتی محیط-35…+70 °C
استانداردهاکمیسیون مستقل انتخابات ۶۰۹۴۷-۲

دریافت قیمت

    ✕

    دریافت قیمت

      ✕

      دانلود کاتالوگ