{"id":8331,"date":"2026-09-07T03:10:11","date_gmt":"2026-09-07T03:10:11","guid":{"rendered":"https:\/\/www.simplybuyglobal.com\/?post_type=product&#038;p=8331"},"modified":"2026-10-10T06:12:19","modified_gmt":"2026-10-10T06:12:19","slug":"schneider-electric-lrd4367-tesys-deca-thermal-overload-relay-95120a-class-10a-55kw-400v-motor-protection","status":"publish","type":"product","link":"https:\/\/www.simplybuyglobal.com\/ru\/product\/schneider-electric-lrd4367-tesys-deca-thermal-overload-relay-95120a-class-10a-55kw-400v-motor-protection\/","title":{"rendered":"Schneider Electric LRD4367 \u0422\u0435\u043f\u043b\u043e\u0432\u043e\u0435 \u0440\u0435\u043b\u0435 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438 TeSys Deca \u2013 95\u2026120\u0410, \u043a\u043b\u0430\u0441\u0441 10\u0410, \u0437\u0430\u0449\u0438\u0442\u0430 \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f 55 \u043a\u0412\u0442 @ 400 \u0412"},"content":{"rendered":"<h2>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u0430<\/h2>\n<p>The Schneider Electric LRD4367 is a differential thermal overload relay from the TeSys Deca range, designed for direct mounting on TeSys D contactors LC1D115 and LC1D150 to form a compact motor starter. It provides thermal protection with an adjustable setting range of 95\u2026120 A and a tripping class of 10A conforming to IEC 60947-4-1, protecting three-phase motors up to 55 kW at 400 V. The relay features phase failure and load unbalance detection, with tripping occurring at 130% of the set current on two phases. It includes a manual test button, a reset button, and a manual\/automatic reset selector, along with 1 NO + 1 NC trip auxiliary contacts and a flag indicator. Temperature compensated from -20\u202660 \u00b0C, it ensures stable protection accuracy across varying ambient conditions. Typical applications include industrial motor control, pumps, fans, and compressors in demanding environments.<\/p>\n<h2>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435 \u0444\u0443\u043d\u043a\u0446\u0438\u0438<\/h2>\n<ul>\n<li><strong>Adjustable Thermal Protection Range:<\/strong> Setting range of 95\u2026120 A allows precise matching to the motor&#8217;s full-load current for reliable overload protection.<\/li>\n<li><strong>\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438 \u0441\u0440\u0430\u0431\u0430\u0442\u044b\u0432\u0430\u043d\u0438\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u043a\u043b\u0430\u0441\u0441\u0430 10A:<\/strong> Conforms to IEC 60947-4-1, providing standard trip times suitable for most industrial motor starting applications.<\/li>\n<li><strong>Phase Failure and Unbalance Detection:<\/strong> Differential mechanism trips at 130% of the set current on two phases, preventing motor damage from supply imbalance.<\/li>\n<li><strong>Direct Mounting on TeSys D Contactors:<\/strong> Mounts directly on the bottom terminals of LC1D115 and LC1D150 contactors to form a compact starter without additional wiring.<\/li>\n<li><strong>\u0420\u0443\u0447\u043d\u043e\u0439 \u0438 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0441\u0431\u0440\u043e\u0441:<\/strong> Includes test and reset buttons plus a selector for manual or automatic reset, with a trip flag indicator for clear status identification.<\/li>\n<li><strong>Temperature Compensated:<\/strong> Maintains accurate protection across an operating temperature range of -20\u202660 \u00b0C without derating.<\/li>\n<li><strong>\u0413\u043b\u043e\u0431\u0430\u043b\u044c\u043d\u044b\u0435 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u044b:<\/strong> Multi-standards certified to IEC, UL, CSA, CCC, EAC, and Marine standards, suitable for worldwide industrial applications.<\/li>\n<\/ul>\n<h2>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u0426\u0435\u043d\u0438\u0442\u044c<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u0428\u043d\u0430\u0439\u0434\u0435\u0440 \u042d\u043b\u0435\u043a\u0442\u0440\u0438\u043a<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u0434\u0435\u043b\u044c<\/td>\n<td>\u041b\u0420\u04144367<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u044f\u0434<\/td>\n<td>TeSys LRD \/ TeSys Deca<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u0438\u043f \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u0430<\/td>\n<td>\u0414\u0438\u0444\u0444\u0435\u0440\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u043e\u0435 \u0442\u0435\u043f\u043b\u043e\u0432\u043e\u0435 \u0440\u0435\u043b\u0435 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438<\/td>\n<\/tr>\n<tr>\n<td>\u0414\u0438\u0430\u043f\u0430\u0437\u043e\u043d \u0440\u0435\u0433\u0443\u043b\u0438\u0440\u043e\u0432\u043a\u0438 \u0442\u0435\u043f\u043b\u043e\u0432\u043e\u0439 \u0437\u0430\u0449\u0438\u0442\u044b<\/td>\n<td>95\u2026120 \u0410<\/td>\n<\/tr>\n<tr>\n<td>\u041a\u043b\u0430\u0441\u0441 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f<\/td>\n<td>\u041a\u043b\u0430\u0441\u0441 10A (IEC 60947-4-1)<\/td>\n<\/tr>\n<tr>\n<td>Motor Power (AC-3 @ 400 V)<\/td>\n<td>55 \u043a\u0412\u0442<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 (Ui)<\/td>\n<td>1000 V (power circuit, IEC 60947-4-1)<\/td>\n<\/tr>\n<tr>\n<td>\u0412\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b<\/td>\n<td>1 \u041d\u041e + 1 \u041d\u0417<\/td>\n<\/tr>\n<tr>\n<td>\u0427\u0443\u0432\u0441\u0442\u0432\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0441\u0442\u044c \u043a \u043e\u0431\u0440\u044b\u0432\u0443 \u0444\u0430\u0437\u044b<\/td>\n<td>Tripping at 130% of Ir on two phases<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u043d\u0430\u044f \u043a\u043e\u043c\u043f\u0435\u043d\u0441\u0430\u0446\u0438\u044f<\/td>\n<td>-20\u202660 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b<\/td>\n<td>EN\/IEC 60947-4-1, EN\/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p dir=\"ltr\"><strong>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c:<\/strong> \u0428\u043d\u0430\u0439\u0434\u0435\u0440 \u042d\u043b\u0435\u043a\u0442\u0440\u0438\u043a<br \/>\n<strong>\u041c\u043e\u0434\u0435\u043b\u044c:<\/strong> \u041b\u0420\u04144367<br \/>\n<strong>\u0422\u0438\u043f:<\/strong> \u0414\u0438\u0444\u0444\u0435\u0440\u0435\u043d\u0446\u0438\u0430\u043b\u044c\u043d\u043e\u0435 \u0442\u0435\u043f\u043b\u043e\u0432\u043e\u0435 \u0440\u0435\u043b\u0435 \u043f\u0435\u0440\u0435\u0433\u0440\u0443\u0437\u043a\u0438<br \/>\n<strong>Thermal Setting Range:<\/strong> 95\u2026120 \u0410<br \/>\n<strong>\u041a\u043b\u0430\u0441\u0441 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f:<\/strong> \u041a\u043b\u0430\u0441\u0441 10\u0410<br \/>\n<strong>\u041c\u043e\u0449\u043d\u043e\u0441\u0442\u044c \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f:<\/strong> 55 kW @ 400 V AC<br \/>\n<strong>\u0412\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b:<\/strong> 1 \u041d\u041e + 1 \u041d\u0417<br \/>\n<strong>\u041e\u0431\u043d\u0430\u0440\u0443\u0436\u0435\u043d\u0438\u0435 \u043e\u0431\u0440\u044b\u0432\u043e\u0432 \u0444\u0430\u0437:<\/strong> \u0414\u0430<\/p>","protected":false},"featured_media":8333,"template":"","meta":[],"product_brand":[],"product_cat":[109,104,19,68,103,102,105,112,101,100,107,106,21,81,111,108],"product_tag":[],"class_list":["post-8331","product","type-product","status-publish","has-post-thumbnail","product_cat-ac","product_cat-air-compressor","product_cat-circuit-breaker","product_cat-control-relays-relay","product_cat-elevator-and-crane","product_cat-fan-and-pumps","product_cat-hvac","product_cat-iec-standards","product_cat-industrial-process","product_cat-motor-control-application","product_cat-new-energy","product_cat-oil-gas","product_cat-relay","product_cat-schneider","product_cat-standard","product_cat-voltage","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product\/8331","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/media\/8333"}],"wp:attachment":[{"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/media?parent=8331"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product_brand?post=8331"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product_cat?post=8331"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product_tag?post=8331"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}