{"id":7724,"date":"2026-08-15T05:39:37","date_gmt":"2026-08-15T05:39:37","guid":{"rendered":"https:\/\/www.simplybuyglobal.com\/?post_type=product&#038;p=7724"},"modified":"2026-08-15T05:42:02","modified_gmt":"2026-08-15T05:42:02","slug":"eaton-moeller-pl9-c10-1-xpole-miniature-circuit-breaker-10a-1-pole-c-curve-230-400v-6ka","status":"publish","type":"product","link":"https:\/\/www.simplybuyglobal.com\/ru\/product\/eaton-moeller-pl9-c10-1-xpole-miniature-circuit-breaker-10a-1-pole-c-curve-230-400v-6ka\/","title":{"rendered":"\u041c\u0438\u043d\u0438\u0430\u0442\u044e\u0440\u043d\u044b\u0439 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c Eaton Moeller PL9-C10\/1 xPole, 10A, 1-\u043f\u043e\u043b\u044e\u0441\u043d\u044b\u0439, C-\u043e\u0431\u0440\u0430\u0437\u043d\u0430\u044f \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430, 230\/400 \u0412, 6 \u043a\u0410."},"content":{"rendered":"<h2>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u0430<\/h2>\n<p>The Eaton Moeller PL9-C10\/1 is a miniature circuit breaker from the xPole PL9 series, designed to protect electrical circuits against overload and short-circuit conditions. Rated at 10 A with a C tripping characteristic, it is suitable for circuits with moderate inrush currents in residential, commercial, and industrial electrical distribution systems. The single-pole breaker operates at 230\/400 V AC and provides a rated breaking capacity of 6 kA. Its thermal-magnetic protection mechanism ensures dependable overcurrent interruption, while the compact modular construction allows convenient installation on standard 35 mm DIN rails in distribution boards and control panels.<\/p>\n<h2>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435 \u0444\u0443\u043d\u043a\u0446\u0438\u0438<\/h2>\n<ul>\n<li><strong>10 A rated current:<\/strong> Provides overcurrent protection for low-voltage electrical distribution circuits.<\/li>\n<li><strong>C tripping characteristic:<\/strong> Suitable for circuits with moderate starting or inrush currents.<\/li>\n<li><strong>6 kA breaking capacity:<\/strong> Provides reliable interruption of short-circuit fault currents.<\/li>\n<li><strong>Single-pole design:<\/strong> Offers compact protection for one-phase circuit conductors.<\/li>\n<li><strong>Thermal-magnetic protection:<\/strong> Combines overload and instantaneous short-circuit protection.<\/li>\n<li><strong>230\/400 V AC rating:<\/strong> Suitable for standard low-voltage AC distribution systems.<\/li>\n<li><strong>DIN-rail mounting:<\/strong> Enables quick installation in modular distribution boards and control panels.<\/li>\n<\/ul>\n<h2>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u0426\u0435\u043d\u0438\u0442\u044c<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u0418\u0442\u043e\u043d \u041c\u0451\u043b\u043b\u0435\u0440<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u0434\u0435\u043b\u044c<\/td>\n<td>PL9-C10\/1<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u044f\u0434<\/td>\n<td>xPole PL9<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u0438\u043f \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u0430<\/td>\n<td>\u041c\u0438\u043d\u0438\u0430\u0442\u044e\u0440\u043d\u044b\u0439 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c (MCB)<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a<\/td>\n<td>10 \u0410<\/td>\n<\/tr>\n<tr>\n<td>\u041a\u043e\u043b\u0438\u0447\u0435\u0441\u0442\u0432\u043e \u043f\u043e\u043b\u044e\u0441\u043e\u0432<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f<\/td>\n<td>\u041a\u0440\u0438\u0432\u0430\u044f \u0421<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435<\/td>\n<td>230\/400 \u0412 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u0430\u044f \u043e\u0442\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0430\u044f \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c<\/td>\n<td>6 \u043a\u0410<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u0438\u043f \u0437\u0430\u0449\u0438\u0442\u044b<\/td>\n<td>\u0422\u0435\u0440\u043c\u043e\u043c\u0430\u0433\u043d\u0438\u0442\u043d\u044b\u0439<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u043d\u0442\u0430\u0436<\/td>\n<td>35 mm DIN Rail<\/td>\n<\/tr>\n<tr>\n<td>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0439<\/td>\n<td>IEC\/EN 60898-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p dir=\"ltr\"><strong>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c:<\/strong> \u0418\u0442\u043e\u043d \u041c\u0451\u043b\u043b\u0435\u0440<br \/>\n<strong>\u041c\u043e\u0434\u0435\u043b\u044c:<\/strong> PL9-C10\/1<br \/>\n<strong>\u0422\u0438\u043f:<\/strong> \u041c\u0438\u043d\u0438\u0430\u0442\u044e\u0440\u043d\u044b\u0439 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0432\u044b\u043a\u043b\u044e\u0447\u0430\u0442\u0435\u043b\u044c<br \/>\n<strong>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a:<\/strong> 10 \u0410<br \/>\n<strong>\u041f\u043e\u043b\u044f\u043a\u0438:<\/strong> 1<br \/>\n<strong>\u0425\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0430 \u043e\u0442\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f:<\/strong> \u041a\u0440\u0438\u0432\u0430\u044f \u0421<br \/>\n<strong>\u041e\u0442\u043a\u043b\u044e\u0447\u0430\u044e\u0449\u0430\u044f \u0441\u043f\u043e\u0441\u043e\u0431\u043d\u043e\u0441\u0442\u044c:<\/strong> 6 \u043a\u0410<\/p>","protected":false},"featured_media":7727,"template":"","meta":[],"product_brand":[],"product_cat":[109,104,19,84,103,102,105,112,101,100,107,106,111,113,108],"product_tag":[],"class_list":["post-7724","product","type-product","status-publish","has-post-thumbnail","product_cat-ac","product_cat-air-compressor","product_cat-circuit-breaker","product_cat-eaton","product_cat-elevator-and-crane","product_cat-fan-and-pumps","product_cat-hvac","product_cat-iec-standards","product_cat-industrial-process","product_cat-motor-control-application","product_cat-new-energy","product_cat-oil-gas","product_cat-standard","product_cat-ul-standards","product_cat-voltage","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product\/7724","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/media\/7727"}],"wp:attachment":[{"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/media?parent=7724"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product_brand?post=7724"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product_cat?post=7724"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product_tag?post=7724"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}