{"id":7466,"date":"2026-08-06T06:47:39","date_gmt":"2026-08-06T06:47:39","guid":{"rendered":"https:\/\/www.simplybuyglobal.com\/?post_type=product&#038;p=7466"},"modified":"2026-10-10T06:45:07","modified_gmt":"2026-10-10T06:45:07","slug":"schneider-electric-lc1d09m7c-tesys-d-3-pole-ac-contactor-9a-ac-3-220v-ac-coil-1no1nc-auxiliary","status":"publish","type":"product","link":"https:\/\/www.simplybuyglobal.com\/ru\/product\/schneider-electric-lc1d09m7c-tesys-d-3-pole-ac-contactor-9a-ac-3-220v-ac-coil-1no1nc-auxiliary\/","title":{"rendered":"\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430 Schneider Electric LC1D09M7C TeSys D, 3-\u043f\u043e\u043b\u044e\u0441\u043d\u044b\u0439, 9 \u0410, AC-3, 220 \u0412, \u043a\u0430\u0442\u0443\u0448\u043a\u0430 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430, 1\u041d\u041e+1\u041d\u0417, \u0432\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0439."},"content":{"rendered":"<h2>\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u0430<\/h2>\n<p>The Schneider Electric LC1D09M7C is a 3-pole TeSys D contactor designed for motor control applications up to 9 A \/ 690 V AC-3 (4 kW at 400 V AC). It features a 220 V AC 50\/60 Hz control coil and comes with 1 NO + 1 NC built-in auxiliary contacts, with the NC contact mirror-certified for safety-related circuits. Connection is made via screw clamp terminals. The compact 45 mm wide design supports DIN-rail mounting or screw fixing, making it suitable for space-constrained panels. The contactor is rated for operating rates up to 3,600 cycles\/hour and ambient temperatures up to 60 \u00b0C, ensuring high reliability in demanding applications. It is multi-standard certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHS\/REACh).<\/p>\n<h2>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u043d\u044b\u0435 \u0444\u0443\u043d\u043a\u0446\u0438\u0438<\/h2>\n<ul>\n<li><strong>9 A \/ 4 kW AC-3 Rating:<\/strong> Suitable for direct-on-line starting of three-phase motors up to 4 kW at 380\u2013400 V AC, with AC-3\/AC-3e utilization category.<\/li>\n<li><strong>220 V AC 50\/60 Hz Coil:<\/strong> Standard control coil voltage for integration with common industrial control circuits.<\/li>\n<li><strong>Built-in 1 NO + 1 NC Auxiliary Contacts:<\/strong> Provides integrated signal contacts for status feedback and interlocking, with NC mirror certification per IEC 60947-4-1.<\/li>\n<li><strong>Compact 45 mm Width:<\/strong> Space-saving design enables DIN-rail mounting or screw fixing, optimizing panel layout.<\/li>\n<li><strong>High Operating Rate:<\/strong> Rated for up to 3,600 cycles\/hour, suitable for frequent switching applications.<\/li>\n<li><strong>IEC 60335-1 Compliance:<\/strong> Improved fire resistance with certification to IEC 60335-1 (Clause 30.2) and anti-flammable refrigerants per IEC\/EN\/UL 60335-2-40 (Annex JJ).<\/li>\n<li><strong>Multi-Standard &amp; Green Premium:<\/strong> Certified to IEC, UL, CSA, CCC, EAC, and Marine standards; Green Premium compliant (RoHS\/REACh), with a total lifecycle carbon footprint of 159 kg CO\u2082 eq.<\/li>\n<\/ul>\n<h2>\u0422\u0435\u0445\u043d\u0438\u0447\u0435\u0441\u043a\u0438\u0435 \u0445\u0430\u0440\u0430\u043a\u0442\u0435\u0440\u0438\u0441\u0442\u0438\u043a\u0438<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u0426\u0435\u043d\u0438\u0442\u044c<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c<\/td>\n<td>\u0428\u043d\u0430\u0439\u0434\u0435\u0440 \u042d\u043b\u0435\u043a\u0442\u0440\u0438\u043a<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u0434\u0435\u043b\u044c<\/td>\n<td>LC1D09M7C<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u044f\u0434<\/td>\n<td>TeSys D \/ TeSys Deca<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u0438\u043f \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u0430<\/td>\n<td>\u041a\u043e\u043d\u0442\u0430\u043a\u0442\u043e\u0440<\/td>\n<\/tr>\n<tr>\n<td>Rated Operational Current (Ie) \u2013 AC-3<\/td>\n<td>9 A (\u2264 440 V AC)<\/td>\n<\/tr>\n<tr>\n<td>Motor Power (AC-3)<\/td>\n<td>4 kW at 380\u2013400 V AC; 2.2 kW at 220\u2013230 V AC<\/td>\n<\/tr>\n<tr>\n<td>Rated Operational Current \u2013 AC-1<\/td>\n<td>25 A (\u2264 440 V AC, at 60 \u00b0C)<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043a\u0430\u0442\u0443\u0448\u043a\u0438<\/td>\n<td>220 \u0412 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430, 50\/60 \u0413\u0446<\/td>\n<\/tr>\n<tr>\n<td>\u0412\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b<\/td>\n<td>1 NO + 1 NC (\u0441\u0435\u0440\u0442\u0438\u0444\u0438\u0446\u0438\u0440\u043e\u0432\u0430\u043d\u043e \u043f\u043e \u0441\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0443 NC)<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u0440\u0430\u0431\u043e\u0447\u0435\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 (Ue)<\/td>\n<td>\u2264 690 V AC (25\u2013400 Hz) \/ \u2264 225 V DC<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u0438\u0437\u043e\u043b\u044f\u0446\u0438\u0438 (Ui)<\/td>\n<td>690 \u0412 (IEC 60947-4-1)<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u043e\u0435 \u0438\u043c\u043f\u0443\u043b\u044c\u0441\u043d\u043e\u0435 \u0432\u044b\u0434\u0435\u0440\u0436\u0438\u0432\u0430\u0435\u043c\u043e\u0435 \u043d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 (Uimp)<\/td>\n<td>6 \u043a\u0412<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u0438\u043f \u043f\u043e\u0434\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u044f<\/td>\n<td>\u0412\u0438\u043d\u0442\u043e\u0432\u044b\u0435 \u043a\u043b\u0435\u043c\u043c\u043d\u044b\u0435 \u0437\u0430\u0436\u0438\u043c\u044b<\/td>\n<\/tr>\n<tr>\n<td>\u0413\u0430\u0431\u0430\u0440\u0438\u0442\u044b (\u0428 \u00d7 \u0412 \u00d7 \u0413)<\/td>\n<td>45 mm \u00d7 77 mm \u00d7 86 mm<\/td>\n<\/tr>\n<tr>\n<td>\u0412\u0435\u0441 \u043d\u0435\u0442\u0442\u043e<\/td>\n<td>0.32 kg<\/td>\n<\/tr>\n<tr>\n<td>\u0421\u0442\u0435\u043f\u0435\u043d\u044c \u0437\u0430\u0449\u0438\u0442\u044b<\/td>\n<td>\u0421\u0442\u0435\u043f\u0435\u043d\u044c \u0437\u0430\u0449\u0438\u0442\u044b IP20 (\u043f\u0435\u0440\u0435\u0434\u043d\u044f\u044f \u043f\u0430\u043d\u0435\u043b\u044c)<\/td>\n<\/tr>\n<tr>\n<td>\u0420\u0430\u0431\u043e\u0447\u0430\u044f \u0442\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430<\/td>\n<td>\u221225 \u00b0C to +60 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u044b \u0438 \u0441\u0435\u0440\u0442\u0438\u0444\u0438\u043a\u0430\u0446\u0438\u044f<\/td>\n<td>IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, CCC, EAC, Marine; Green Premium (RoHS\/REACh)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p dir=\"ltr\"><strong>\u041f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u044c:<\/strong> \u0428\u043d\u0430\u0439\u0434\u0435\u0440 \u042d\u043b\u0435\u043a\u0442\u0440\u0438\u043a<br \/>\n<strong>\u041c\u043e\u0434\u0435\u043b\u044c:<\/strong> LC1D09M7C<br \/>\n<strong>\u0422\u0438\u043f:<\/strong> TeSys D Contactor<br \/>\n<strong>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u044c\u043d\u044b\u0439 \u0442\u043e\u043a:<\/strong> 9 \u0410 (AC-3)<br \/>\n<strong>\u041c\u043e\u0449\u043d\u043e\u0441\u0442\u044c \u0434\u0432\u0438\u0433\u0430\u0442\u0435\u043b\u044f:<\/strong> 4 kW @ 400 V AC<br \/>\n<strong>\u041d\u0430\u043f\u0440\u044f\u0436\u0435\u043d\u0438\u0435 \u043a\u0430\u0442\u0443\u0448\u043a\u0438:<\/strong> 220 \u0412 \u043f\u0435\u0440\u0435\u043c\u0435\u043d\u043d\u043e\u0433\u043e \u0442\u043e\u043a\u0430, 50\/60 \u0413\u0446<br \/>\n<strong>\u0412\u0441\u043f\u043e\u043c\u043e\u0433\u0430\u0442\u0435\u043b\u044c\u043d\u044b\u0435 \u043a\u043e\u043d\u0442\u0430\u043a\u0442\u044b:<\/strong> 1 \u041d\u041e + 1 \u041d\u0417<\/p>","protected":false},"featured_media":7580,"template":"","meta":[],"product_brand":[],"product_cat":[42,104,110,103,102,105,112,101,100,107,106,81],"product_tag":[],"class_list":["post-7466","product","type-product","status-publish","has-post-thumbnail","product_cat-ac-contactor","product_cat-air-compressor","product_cat-dc","product_cat-elevator-and-crane","product_cat-fan-and-pumps","product_cat-hvac","product_cat-iec-standards","product_cat-industrial-process","product_cat-motor-control-application","product_cat-new-energy","product_cat-oil-gas","product_cat-schneider","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product\/7466","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/media\/7580"}],"wp:attachment":[{"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/media?parent=7466"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product_brand?post=7466"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product_cat?post=7466"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ru\/wp-json\/wp\/v2\/product_tag?post=7466"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}