{"id":8480,"date":"2026-09-14T05:14:19","date_gmt":"2026-09-14T05:14:19","guid":{"rendered":"https:\/\/www.simplybuyglobal.com\/?post_type=product&#038;p=8480"},"modified":"2026-09-14T05:19:40","modified_gmt":"2026-09-14T05:19:40","slug":"mitsubishi-electric-nv63-cv-3p-30a-earth-leakage-circuit-breaker-30a-3-pole-30ma-sensitivity-5ka-400v","status":"publish","type":"product","link":"https:\/\/www.simplybuyglobal.com\/ko\/product\/mitsubishi-electric-nv63-cv-3p-30a-earth-leakage-circuit-breaker-30a-3-pole-30ma-sensitivity-5ka-400v\/","title":{"rendered":"\ubbf8\uc4f0\ube44\uc2dc \uc804\uae30 NV63-CV 3P 30A \ub204\uc804 \ucc28\ub2e8\uae30 \u2013 30A, 3\uadf9, 30mA \uac10\ub3c4, 5kA @ 400V"},"content":{"rendered":"<h2>Mitsubishi Electric NV63-CV 3P 30A Earth Leakage Circuit Breaker \u2013 30A, 3\u2011Pole, 30mA Sensitivity, 5kA @ 400V<\/h2>\n<p dir=\"ltr\"><strong>Manufacturer:<\/strong> Mitsubishi Electric<br \/>\n<strong>Model:<\/strong> NV63-CV 3P 30A<br \/>\n<strong>Type:<\/strong> Earth Leakage Circuit Breaker (ELCB) \/ Molded Case Circuit Breaker with Earth Leakage Protection<br \/>\n<strong>Series:<\/strong> WS-V \/ NV-C (Economy Class)<br \/>\n<strong>Rated Current (In):<\/strong> 30A<br \/>\n<strong>Number of Poles:<\/strong> 3\u2011pole (3P)<br \/>\n<strong>Rated Sensitivity Current:<\/strong> 30mA<br \/>\n<strong>Breaking Capacity (Icu @ 400V AC):<\/strong> 5kA<br \/>\n<strong>Application:<\/strong> Earth leakage, overload, and short-circuit protection in distribution boards and machinery<\/p>\n<p dir=\"ltr\">The Mitsubishi Electric NV63-CV 3P 30A is a compact earth leakage circuit breaker from the WS-V series, designed to provide comprehensive protection against earth leakage, overload, and short circuits in industrial and commercial power distribution systems. Combining a thermal-magnetic trip unit with high-speed earth leakage detection, it delivers reliable protection for personnel and equipment. The breaker features a 30mA rated sensitivity current with a maximum operating time of 0.1 seconds, ensuring rapid disconnection under fault conditions. Its compact dimensions (75mm W \u00d7 130mm H \u00d7 90mm D) and front lug\/bar connection design make it ideal for panel builders seeking a space-efficient solution. Compliant with IEC 60947-2 and CE marked, the NV63-CV is suitable for global applications.[reference:0]<\/p>\n<div>\n<ul class=\"tight\" dir=\"ltr\" data-tight=\"true\">\n<li>\n<p dir=\"ltr\"><strong>Combined Earth Leakage &amp; Overcurrent Protection<\/strong>: Integrates earth leakage protection with thermal-magnetic overcurrent protection in a single compact device, reducing panel space and wiring complexity.<\/p>\n<\/li>\n<li>\n<p dir=\"ltr\"><strong>High-Speed Earth Leakage Detection<\/strong>: 30mA rated sensitivity current with a maximum operating time of 0.1 seconds at I\u0394n, ensuring rapid disconnection to protect personnel and equipment.<\/p>\n<\/li>\n<li>\n<p dir=\"ltr\"><strong>Reliable Breaking Capacity<\/strong>: Delivers 5kA Icu at 400V AC and 7.5kA at 230V AC, providing robust fault current interruption for industrial and commercial applications.[reference:1]<\/p>\n<\/li>\n<li>\n<p dir=\"ltr\"><strong>Compact &amp; Space-Saving Design<\/strong>: 75mm width \u00d7 130mm height \u00d7 90mm depth with front lug or bar connections, ideal for space-constrained distribution boards.<\/p>\n<\/li>\n<li>\n<p dir=\"ltr\"><strong>Harmonic &amp; Surge Ready<\/strong>: Designed to be compatible with harmonic and surge conditions, ensuring reliable operation in modern power environments with non-linear loads.<\/p>\n<\/li>\n<li>\n<p dir=\"ltr\"><strong>Manual Test &amp; Reset<\/strong>: Features a mechanical test button for periodic verification of earth leakage function and a manual reset mechanism for easy operation and maintenance.<\/p>\n<\/li>\n<li>\n<p dir=\"ltr\"><strong>Global Compliance<\/strong>: Certified to IEC 60947-2 and EN 60947-2, CE marked, with a pollution degree 2 rating suitable for worldwide industrial applications.[reference:2]<\/p>\n<\/li>\n<\/ul>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<table style=\"width: 775px; height: auto;\">\n<thead>\n<tr>\n<th style=\"background-color: #152c76; color: white; width: 143.438px;\"><span style=\"font-size: 14px;\">\ub9e4\uac1c\ubcc0\uc218<\/span><\/th>\n<th style=\"background-color: #152c76; color: white; width: 288.562px;\"><span style=\"font-size: 14px;\">\uac12<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"text-align: left;\">\n<td>\uc81c\ud488 \uc720\ud615<\/td>\n<td>\ub204\uc804 \ucc28\ub2e8\uae30 (ELCB)<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\uc2dc\ub9ac\uc988\/\ube0c\ub79c\ub4dc<\/td>\n<td>WS-V \/ NV-C \uc2dc\ub9ac\uc988 \u2013 Mitsubishi Electric<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\ubaa8\ub378 \ubc88\ud638<\/td>\n<td>NV63-CV 3P 30A<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\uc804\ubd07\ub300 \uac1c\uc218<\/td>\n<td>3\uadf9 (3P)<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\uc815\uaca9 \uc804\ub958(\uc778\uce58)<\/td>\n<td>30A (\uc8fc\uc704 \uc628\ub3c4 40\u00b0C \uae30\uc900)<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\ud504\ub808\uc784 \uc0ac\uc774\uc988 (AF)<\/td>\n<td>50 AF<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\uc815\uaca9 \ub204\uc804 \uac10\ub3c4 \uc804\ub958<\/td>\n<td>30mA (100\/200\/500mA \uc870\uc808 \uac00\ub2a5 \uc635\uc158 \uc81c\uacf5)<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\ucd5c\ub300 \ub3d9\uc791 \uc2dc\uac04<\/td>\n<td>I\u0394n\uc5d0\uc11c 0.1\ucd08 \/ 5I\u0394n\uc5d0\uc11c 0.04\ucd08<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\uc815\uaca9 \uc804\uc555(\uad50\ub958)<\/td>\n<td>100\u2013440 V<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\uc815\uaca9 \uc784\ud384\uc2a4 \ub0b4\uc804\uc555(Uimp)<\/td>\n<td>6kV<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\ucc28\ub2e8 \uc6a9\ub7c9 (Icu) @ AC 100V<\/td>\n<td>5 kA<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\ucc28\ub2e8 \uc6a9\ub7c9 (Icu) @ AC 200V<\/td>\n<td>5 kA<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\ucc28\ub2e8 \uc6a9\ub7c9 (Icu) @ AC 230V<\/td>\n<td>5 kA<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\ucc28\ub2e8 \uc6a9\ub7c9 (Icu) @ AC 400V<\/td>\n<td>5 kA<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\ucc28\ub2e8 \uc6a9\ub7c9 (Icu) @ AC 415V<\/td>\n<td>5 kA<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\ucc28\ub2e8 \uc6a9\ub7c9 (Icu) @ AC 440V<\/td>\n<td>5 kA<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\uc11c\ube44\uc2a4 \uc911\ub2e8 \uc6a9\ub7c9(ICS)<\/td>\n<td>AC 400V\uc5d0\uc11c Icu\uc758 100%<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\ud2b8\ub9bd \uc720\ub2db \uc720\ud615<\/td>\n<td>\uc5f4 \uc790\uae30\uc2dd (\uace0\uc815\ud615) \ub204\uc804 \uc694\uc18c \ud3ec\ud568<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\ubcf4\ud638 \uae30\ub2a5<\/td>\n<td>\uacfc\ubd80\ud558, \ub2e8\ub77d, \ub204\uc804<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\uc5f0\uacb0 \uc720\ud615<\/td>\n<td>\uc804\uba74 \ub7ec\uadf8 \ub610\ub294 \ubc14 \uc5f0\uacb0<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\uc124\uce58<\/td>\n<td>\ud45c\uba74 \uc2e4\uc7a5 (\uc635\uc158 \uc5b4\ub311\ud130 \ud3ec\ud568 DIN \ub808\uc77c)<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\ud06c\uae30 (\uac00\ub85c \u00d7 \uc138\ub85c \u00d7 \uae4a\uc774)<\/td>\n<td>75 mm \u00d7 130 mm \u00d7 90 mm<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\uc21c\uc911\ub7c9<\/td>\n<td>\uc57d 0.75 kg<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\uc804\uae30\uc801 \ub0b4\uad6c \uc218\uba85 (\ubd80\ud558 \uc6b4\uc804 \uc2dc)<\/td>\n<td>6,000 \ud68c<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\uae30\uacc4\uc801 \ub0b4\uad6c \uc218\uba85 (\ubb34\ubd80\ud558 \uc2dc)<\/td>\n<td>10,000\uac74\uc758 \uc791\uc5c5<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\ud65c\uc6a9 \ubc94\uc8fc<\/td>\n<td>A<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\uc624\uc5fc \ub4f1\uae09<\/td>\n<td>2<\/td>\n<\/tr>\n<tr style=\"text-align: left;\">\n<td>\ud45c\uc900 \ubc0f \uc778\uc99d<\/td>\n<td>IEC 60947-2, EN 60947-2, CE \ub9c8\ud06c<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"featured_media":8483,"template":"","meta":[],"product_brand":[],"product_cat":[104,103,102,105,112,101,49,87,100,107,106,111],"product_tag":[],"class_list":["post-8480","product","type-product","status-publish","has-post-thumbnail","product_cat-air-compressor","product_cat-elevator-and-crane","product_cat-fan-and-pumps","product_cat-hvac","product_cat-iec-standards","product_cat-industrial-process","product_cat-mccb","product_cat-mitsubishi","product_cat-motor-control-application","product_cat-new-energy","product_cat-oil-gas","product_cat-standard","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.simplybuyglobal.com\/ko\/wp-json\/wp\/v2\/product\/8480","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.simplybuyglobal.com\/ko\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.simplybuyglobal.com\/ko\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ko\/wp-json\/wp\/v2\/media\/8483"}],"wp:attachment":[{"href":"https:\/\/www.simplybuyglobal.com\/ko\/wp-json\/wp\/v2\/media?parent=8480"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ko\/wp-json\/wp\/v2\/product_brand?post=8480"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ko\/wp-json\/wp\/v2\/product_cat?post=8480"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/ko\/wp-json\/wp\/v2\/product_tag?post=8480"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}