{"id":8468,"date":"2026-09-14T03:37:40","date_gmt":"2026-09-14T03:37:40","guid":{"rendered":"https:\/\/www.simplybuyglobal.com\/?post_type=product&#038;p=8468"},"modified":"2026-10-10T06:17:01","modified_gmt":"2026-10-10T06:17:01","slug":"schneider-electric-lrd4369-tesys-deca-thermal-overload-relay-110140a-class-10a-75kw-400v-motor-protection","status":"publish","type":"product","link":"https:\/\/www.simplybuyglobal.com\/kk\/product\/schneider-electric-lrd4369-tesys-deca-thermal-overload-relay-110140a-class-10a-75kw-400v-motor-protection\/","title":{"rendered":"Schneider Electric LRD4369 TeSys Deca \u0422\u0435\u0440\u043c\u0430\u043b\u0434\u044b \u049b\u043e\u0440\u0493\u0430\u0443 \u0440\u0435\u043b\u0435\u0441\u0456 \u2013 110\u2026140\u0410, \u041a\u043b\u0430\u0441\u0441 10\u0410, 400\u0412-\u0442\u0430 75\u043a\u0412\u0442 \u049b\u043e\u0437\u0493\u0430\u043b\u0442\u049b\u044b\u0448\u0442\u044b \u049b\u043e\u0440\u0493\u0430\u0443"},"content":{"rendered":"<h2>\u04e8\u043d\u0456\u043c \u0441\u0438\u043f\u0430\u0442\u0442\u0430\u043c\u0430\u0441\u044b<\/h2>\n<p>The Schneider Electric LRD4369 is a differential thermal overload relay from the TeSys Deca range, designed for direct mounting under the LC1D150 contactor to form a compact motor starter. It provides thermal protection with an adjustable setting range of 110\u2026140 A and a tripping class of 10A conforming to IEC 60947-4-1, suitable for protecting three-phase motors up to 75 kW at 400 V AC. The relay features phase failure and load unbalance detection, with tripping occurring at 130% of the set current on two phases. It includes a manual test button, a reset button, and a manual\/automatic reset selector, along with 1 NO + 1 NC trip auxiliary contacts. Temperature compensated from -20\u202660 \u00b0C, it ensures stable protection accuracy across varying ambient conditions. Typical applications include industrial motor control, pumps, fans, and compressors in demanding environments.<\/p>\n<h2>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0442\u044b \u043c\u04af\u043c\u043a\u0456\u043d\u0434\u0456\u043a\u0442\u0435\u0440<\/h2>\n<ul>\n<li><strong>Adjustable Thermal Protection Range:<\/strong> Setting range of 110\u2026140 A allows precise matching to the motor&#8217;s full-load current for reliable overload protection.<\/li>\n<li><strong>10A \u043a\u043b\u0430\u0441\u044b\u043d\u044b\u04a3 \u0442\u0430\u0439\u044b\u043f \u043a\u0435\u0442\u0443 \u0441\u0438\u043f\u0430\u0442\u0442\u0430\u043c\u0430\u0441\u044b:<\/strong> Conforms to IEC 60947-4-1, providing standard trip times suitable for most industrial motor starting applications.<\/li>\n<li><strong>Phase Failure and Unbalance Detection:<\/strong> Differential mechanism trips at 130% of the set current on two phases, preventing motor damage from supply imbalance.<\/li>\n<li><strong>Direct Mounting on LC1D150 Contactor:<\/strong> Mounts directly under the contactor to form a compact starter without additional wiring or accessories.<\/li>\n<li><strong>\u049a\u043e\u043b\u043c\u0435\u043d \u0436\u04d9\u043d\u0435 \u0430\u0432\u0442\u043e\u043c\u0430\u0442\u0442\u044b \u0442\u04af\u0440\u0434\u0435 \u049b\u0430\u043b\u043f\u044b\u043d\u0430 \u043a\u0435\u043b\u0442\u0456\u0440\u0443:<\/strong> Includes test and reset buttons plus a selector for manual or automatic reset, with a trip flag indicator for clear status identification.<\/li>\n<li><strong>Temperature Compensated:<\/strong> Maintains accurate protection across an operating temperature range of -20\u202660 \u00b0C without derating.<\/li>\n<li><strong>Global Approvals &amp; Marine Compliance:<\/strong> Multi-standards certified to IEC, UL, CSA, CCC, EAC, and Marine standards, with IACS E10 climate resistance for worldwide applications.<\/li>\n<\/ul>\n<h2>\u0422\u0435\u0445\u043d\u0438\u043a\u0430\u043b\u044b\u049b \u0441\u0438\u043f\u0430\u0442\u0442\u0430\u043c\u0430\u043b\u0430\u0440<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440<\/th>\n<th>\u049a\u04b1\u043d\u0434\u044b\u043b\u044b\u049b<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u04e8\u043d\u0434\u0456\u0440\u0443\u0448\u0456<\/td>\n<td>Schneider Electric<\/td>\n<\/tr>\n<tr>\n<td>\u041c\u043e\u0434\u0435\u043b\u044c<\/td>\n<td>LRD4369<\/td>\n<\/tr>\n<tr>\n<td>\u0421\u0435\u0440\u0438\u044f\u043b\u0430\u0440<\/td>\n<td>TeSys LRD \/ TeSys Deca<\/td>\n<\/tr>\n<tr>\n<td>\u04e8\u043d\u0456\u043c \u0442\u04af\u0440\u0456<\/td>\n<td>\u0414\u0438\u0444\u0444\u0435\u0440\u0435\u043d\u0446\u0438\u0430\u043b\u0434\u044b \u0436\u044b\u043b\u0443\u043b\u044b\u049b \u0448\u0430\u043c\u0430\u0434\u0430\u043d \u0442\u044b\u0441 \u0436\u04af\u043a\u0442\u0435\u043b\u0443\u0434\u0435\u043d \u049b\u043e\u0440\u0493\u0430\u0443 \u0440\u0435\u043b\u0435\u0441\u0456<\/td>\n<\/tr>\n<tr>\n<td>\u0416\u044b\u043b\u0443\u043b\u044b\u049b \u049b\u043e\u0440\u0493\u0430\u0443\u0434\u044b \u0440\u0435\u0442\u0442\u0435\u0443 \u0434\u0438\u0430\u043f\u0430\u0437\u043e\u043d\u044b<\/td>\n<td>110\u2026140 \u0410<\/td>\n<\/tr>\n<tr>\n<td>\u0421\u0430\u044f\u0445\u0430\u0442\u0442\u0430\u0443 \u0441\u0430\u0431\u0430\u0493\u044b<\/td>\n<td>10\u0410 \u043a\u043b\u0430\u0441\u044b (IEC 60947-4-1)<\/td>\n<\/tr>\n<tr>\n<td>Motor Power (AC-3 @ 400 V)<\/td>\n<td>75 \u043a\u0412\u0442<\/td>\n<\/tr>\n<tr>\n<td>\u041d\u043e\u043c\u0438\u043d\u0430\u043b\u0434\u044b \u043e\u049b\u0448\u0430\u0443\u043b\u0430\u0443 \u043a\u0435\u0440\u043d\u0435\u0443\u0456 (Ui)<\/td>\n<td>1000 V (power circuit, IEC 60947-4-1)<\/td>\n<\/tr>\n<tr>\n<td>\u041a\u04e9\u043c\u0435\u043a\u0448\u0456 \u0431\u0430\u0439\u043b\u0430\u043d\u044b\u0441\u0442\u0430\u0440<\/td>\n<td>1 \u0416\u041e\u049a + 1 NC<\/td>\n<\/tr>\n<tr>\n<td>\u0424\u0430\u0437\u0430\u043d\u044b\u04a3 \u0456\u0441\u0442\u0435\u043d \u0448\u044b\u0493\u0443 \u0441\u0435\u0437\u0456\u043c\u0442\u0430\u043b\u0434\u044b\u0493\u044b<\/td>\n<td>Tripping at 130% of Ir on two phases<\/td>\n<\/tr>\n<tr>\n<td>\u0422\u0435\u043c\u043f\u0435\u0440\u0430\u0442\u0443\u0440\u0430\u043d\u044b \u043a\u043e\u043c\u043f\u0435\u043d\u0441\u0430\u0446\u0438\u044f\u043b\u0430\u0443<\/td>\n<td>-20\u202660 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u04e8\u043b\u0448\u0435\u043c\u0434\u0435\u0440\u0456 (\u0415 \u00d7 \u0411\u0438 \u00d7 \u0422)<\/td>\n<td>105 mm \u00d7 138 mm \u00d7 132 mm<\/td>\n<\/tr>\n<tr>\n<td>\u0421\u0442\u0430\u043d\u0434\u0430\u0440\u0442\u0442\u0430\u0440<\/td>\n<td>IEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p dir=\"ltr\"><strong>\u04e8\u043d\u0434\u0456\u0440\u0443\u0448\u0456:<\/strong> Schneider Electric<br \/>\n<strong>\u041c\u043e\u0434\u0435\u043b\u044c:<\/strong> LRD4369<br \/>\n<strong>\u0422\u04af\u0440\u0456:<\/strong> \u0414\u0438\u0444\u0444\u0435\u0440\u0435\u043d\u0446\u0438\u0430\u043b\u0434\u044b \u0436\u044b\u043b\u0443\u043b\u044b\u049b \u0448\u0430\u043c\u0430\u0434\u0430\u043d \u0442\u044b\u0441 \u0436\u04af\u043a\u0442\u0435\u043b\u0443\u0434\u0435\u043d \u049b\u043e\u0440\u0493\u0430\u0443 \u0440\u0435\u043b\u0435\u0441\u0456<br \/>\n<strong>Thermal Setting Range:<\/strong> 110\u2026140 \u0410<br \/>\n<strong>\u0421\u0430\u044f\u0445\u0430\u0442 \u043a\u043b\u0430\u0441\u044b:<\/strong> 10\u0410 \u0441\u044b\u043d\u044b\u0431\u044b<br \/>\n<strong>\u049a\u043e\u0437\u0493\u0430\u043b\u0442\u049b\u044b\u0448 \u049b\u0443\u0430\u0442\u044b:<\/strong> 75 kW @ 400 V AC<br \/>\n<strong>\u041a\u04e9\u043c\u0435\u043a\u0448\u0456 \u0431\u0430\u0439\u043b\u0430\u043d\u044b\u0441\u0442\u0430\u0440:<\/strong> 1 \u0416\u041e\u049a + 1 NC<br \/>\n<strong>\u0424\u0430\u0437\u0430\u043b\u044b\u049b \u0430\u049b\u0430\u0443\u043b\u0430\u0440\u0434\u044b \u0430\u043d\u044b\u049b\u0442\u0430\u0443:<\/strong> \u0418\u04d9<\/p>","protected":false},"featured_media":8470,"template":"","meta":[],"product_brand":[],"product_cat":[109,104,19,68,103,102,105,112,101,100,107,106,21,81,111,108],"product_tag":[],"class_list":["post-8468","product","type-product","status-publish","has-post-thumbnail","product_cat-ac","product_cat-air-compressor","product_cat-circuit-breaker","product_cat-control-relays-relay","product_cat-elevator-and-crane","product_cat-fan-and-pumps","product_cat-hvac","product_cat-iec-standards","product_cat-industrial-process","product_cat-motor-control-application","product_cat-new-energy","product_cat-oil-gas","product_cat-relay","product_cat-schneider","product_cat-standard","product_cat-voltage","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.simplybuyglobal.com\/kk\/wp-json\/wp\/v2\/product\/8468","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.simplybuyglobal.com\/kk\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.simplybuyglobal.com\/kk\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/kk\/wp-json\/wp\/v2\/media\/8470"}],"wp:attachment":[{"href":"https:\/\/www.simplybuyglobal.com\/kk\/wp-json\/wp\/v2\/media?parent=8468"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/kk\/wp-json\/wp\/v2\/product_brand?post=8468"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/kk\/wp-json\/wp\/v2\/product_cat?post=8468"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/kk\/wp-json\/wp\/v2\/product_tag?post=8468"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}