{"id":7619,"date":"2026-08-11T02:28:47","date_gmt":"2026-08-11T02:28:47","guid":{"rendered":"https:\/\/www.simplybuyglobal.com\/?post_type=product&#038;p=7619"},"modified":"2026-10-10T06:54:32","modified_gmt":"2026-10-10T06:54:32","slug":"siemens-3ru6126-4ab0-sirius-thermal-overload-relay-11-16a-class-10-s0-screw-terminals","status":"publish","type":"product","link":"https:\/\/www.simplybuyglobal.com\/fa\/product\/siemens-3ru6126-4ab0-sirius-thermal-overload-relay-11-16a-class-10-s0-screw-terminals\/","title":{"rendered":"\u0631\u0644\u0647 \u062d\u0631\u0627\u0631\u062a\u06cc \u0627\u0636\u0627\u0641\u0647 \u0628\u0627\u0631 SIRIUS \u0632\u06cc\u0645\u0646\u0633 3RU6126-4AB0 11-16A \u06a9\u0644\u0627\u0633 10 S0 \u0628\u0627 \u062a\u0631\u0645\u06cc\u0646\u0627\u0644\u200c\u0647\u0627\u06cc \u067e\u06cc\u0686\u06cc"},"content":{"rendered":"<h2>\u062a\u0648\u0636\u06cc\u062d\u0627\u062a \u0645\u062d\u0635\u0648\u0644<\/h2>\n<p>The Siemens 3RU6126-4AB0 is a three-pole thermal overload relay from the SIRIUS 3RU6 series, designed for reliable motor protection against overload and phase failure in industrial applications. It features a front-adjustable, ambient temperature-compensated bimetallic trip mechanism with a current setting range of 11\u202616 A and a trip class of CLASS 10. The relay mounts directly onto Siemens 3RT6 contactors (size S0), forming a compact motor starter without additional wiring. It provides one normally closed (NC) contact for tripping the control circuit and one normally open (NO) contact for remote alarm indication. The main and auxiliary circuits use screw-type terminals. Typical applications include pumps, fans, conveyors, and compressors in industrial automation and building systems.<\/p>\n<h2>\u0648\u06cc\u0698\u06af\u06cc\u200c\u0647\u0627\u06cc \u0627\u0633\u062a\u0627\u0646\u062f\u0627\u0631\u062f<\/h2>\n<ul>\n<li><strong>11\u202616 A Adjustable Setting Range:<\/strong> Front-accessible adjuster knob allows precise matching to the motor&#8217;s full-load current for optimal overload protection.<\/li>\n<li><strong>CLASS 10 Tripping Characteristic:<\/strong> Conforms to IEC 60947-4-1, providing standard trip times suitable for most industrial motor starting applications.<\/li>\n<li><strong>\u062c\u0628\u0631\u0627\u0646 \u062f\u0645\u0627\u06cc \u0645\u062d\u06cc\u0637:<\/strong> Bimetallic trip mechanism compensates for ambient temperature variations from -40 to +70 \u00b0C, ensuring stable protection accuracy.<\/li>\n<li><strong>Single-Phase Protection:<\/strong> Internal differential mechanism detects phase loss and shifts the trip curve to protect the motor from single-phasing damage.<\/li>\n<li><strong>Manual or Automatic Reset:<\/strong> Factory-set for manual (HAND) reset; can be switched to automatic (AUTO) mode by rotating the blue reset button for flexible operation.<\/li>\n<li><strong>Direct Contactor Mounting (Size S0):<\/strong> Mounts directly onto 3RT6 contactors without additional wiring, forming a compact and cost-effective motor starter.<\/li>\n<li><strong>Auxiliary Contacts 1 NO + 1 NC:<\/strong> Provides one NC contact for tripping the control circuit and one NO contact for remote alarm signaling.<\/li>\n<\/ul>\n<h2>\u0645\u0634\u062e\u0635\u0627\u062a \u0641\u0646\u06cc<\/h2>\n<table>\n<thead>\n<tr>\n<th>\u067e\u0627\u0631\u0627\u0645\u062a\u0631<\/th>\n<th>\u0627\u0631\u0632\u0634<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u062a\u0648\u0644\u06cc\u062f\u06a9\u0646\u0646\u062f\u0647<\/td>\n<td>\u0632\u06cc\u0645\u0646\u0633<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u062f\u0644<\/td>\n<td>3RU6126-4AB0<\/td>\n<\/tr>\n<tr>\n<td>\u0633\u0631\u06cc<\/td>\n<td>\u0633\u06cc\u0631\u06cc\u0648\u0633 \u06f3RU6<\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0648\u0639 \u0645\u062d\u0635\u0648\u0644<\/td>\n<td>\u0631\u0644\u0647 \u0627\u0636\u0627\u0641\u0647 \u0628\u0627\u0631 \u062d\u0631\u0627\u0631\u062a\u06cc<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u062d\u062f\u0648\u062f\u0647 \u062a\u0646\u0638\u06cc\u0645<\/td>\n<td>11\u202616 A<\/td>\n<\/tr>\n<tr>\n<td>\u06a9\u0644\u0627\u0633 \u0633\u0641\u0631<\/td>\n<td>\u06a9\u0644\u0627\u0633 \u062f\u0647\u0645<\/td>\n<\/tr>\n<tr>\n<td>\u062c\u0631\u06cc\u0627\u0646 \u0639\u0645\u0644\u06cc\u0627\u062a\u06cc \u0646\u0627\u0645\u06cc<\/td>\n<td>\u06f1\u06f6 \u0627\u0644\u0641<\/td>\n<\/tr>\n<tr>\n<td>\u0648\u0644\u062a\u0627\u0698 \u0639\u0645\u0644\u06cc\u0627\u062a\u06cc \u0646\u0627\u0645\u06cc<\/td>\n<td>\u06f6\u06f9\u06f0 \u0648\u0644\u062a \u0645\u062a\u0646\u0627\u0648\u0628<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0639\u062f\u0627\u062f \u0642\u0637\u0628\u200c\u0647\u0627<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0635\u0628<\/td>\n<td>Direct contactor mounting (Size S0)<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0628\u0639\u0627\u062f (\u0639\u0631\u0636 \u00d7 \u0627\u0631\u062a\u0641\u0627\u0639 \u00d7 \u0639\u0645\u0642)<\/td>\n<td>45 mm \u00d7 85 mm \u00d7 85 mm<\/td>\n<\/tr>\n<tr>\n<td>\u0648\u0632\u0646 \u062e\u0627\u0644\u0635<\/td>\n<td>0.16 kg<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0633\u062a\u0627\u0646\u062f\u0627\u0631\u062f\u0647\u0627<\/td>\n<td>\u06a9\u0645\u06cc\u0633\u06cc\u0648\u0646 \u0645\u0633\u062a\u0642\u0644 \u0627\u0646\u062a\u062e\u0627\u0628\u0627\u062a \u06f6\u06f0\u06f9\u06f4\u06f7-\u06f4-\u06f1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p dir=\"ltr\"><strong>\u0633\u0627\u0632\u0646\u062f\u0647:<\/strong> \u0632\u06cc\u0645\u0646\u0633<br \/>\n<strong>\u0645\u062f\u0644:<\/strong> 3RU6126-4AB0<br \/>\n<strong>\u0646\u0648\u0639:<\/strong> SIRIUS 3RU6 Thermal Overload Relay<br \/>\n<strong>\u0645\u062d\u062f\u0648\u062f\u0647 \u062a\u0646\u0638\u06cc\u0645:<\/strong> 11\u202616 A<br \/>\n<strong>\u06a9\u0644\u0627\u0633 \u0633\u0641\u0631:<\/strong> \u06a9\u0644\u0627\u0633 \u062f\u0647\u0645<br \/>\n<strong>\u062c\u0631\u06cc\u0627\u0646 \u0639\u0645\u0644\u06cc\u0627\u062a\u06cc \u0646\u0627\u0645\u06cc:<\/strong> \u06f1\u06f6 \u0627\u0644\u0641<br \/>\n<strong>\u0648\u0644\u062a\u0627\u0698 \u0639\u0645\u0644\u06cc\u0627\u062a\u06cc \u0646\u0627\u0645\u06cc:<\/strong> \u06f6\u06f9\u06f0 \u0648\u0644\u062a \u0645\u062a\u0646\u0627\u0648\u0628<br \/>\n<strong>\u0646\u0635\u0628:<\/strong> Direct contactor mounting (Size S0)<\/p>","protected":false},"featured_media":7620,"template":"","meta":[],"product_brand":[],"product_cat":[104,99,103,102,105,112,101,100,107,106,21,82],"product_tag":[],"class_list":["post-7619","product","type-product","status-publish","has-post-thumbnail","product_cat-air-compressor","product_cat-application","product_cat-elevator-and-crane","product_cat-fan-and-pumps","product_cat-hvac","product_cat-iec-standards","product_cat-industrial-process","product_cat-motor-control-application","product_cat-new-energy","product_cat-oil-gas","product_cat-relay","product_cat-siemens","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.simplybuyglobal.com\/fa\/wp-json\/wp\/v2\/product\/7619","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.simplybuyglobal.com\/fa\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.simplybuyglobal.com\/fa\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/fa\/wp-json\/wp\/v2\/media\/7620"}],"wp:attachment":[{"href":"https:\/\/www.simplybuyglobal.com\/fa\/wp-json\/wp\/v2\/media?parent=7619"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/fa\/wp-json\/wp\/v2\/product_brand?post=7619"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/fa\/wp-json\/wp\/v2\/product_cat?post=7619"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.simplybuyglobal.com\/fa\/wp-json\/wp\/v2\/product_tag?post=7619"}],"curies":[{"name":"\u0648\u0631\u062f\u067e\u0631\u0633","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}